Range NVe

 

link to proportional control of air heaters NVe

 

Catalogue

Download: Electrical air heaters range NV.e

Electrical air heaters range NV.e

 

GENERAL TECHNICAL DATA

The air heaters, range NV.e are manufactured from black steel sheets with powder coating (RAL 6019), provided for three-phase power and voltage 220 V.

The air heaters are available in three performances:

  1. Units without automatic control and monitoring (NV.e/O);
  2. Units with built-in synchronous switcher for control of room/zone temperature (NV.e/R);
  3. Units with built-in synchronous switcher for control of room/zone temperature and the temperature of the delivered air (NV.e/R.T);

 

All electrical air-heaters, despite of their performance, are equipped with protection thermostat, protecting the unit of overheating.

 

The built-in heating coils, according to the type of control, are connected as follows:

  • All together in a common heating package- in the version of automatic control and monitoring (NV.e/R);
  • In-groups, which can be switched all together or separately, according to the needs of the moment - in the version of manual control and monitoring (NV.e/O).

 

The air heater should be installed in the duct system after the fan. Between the fan and the heater there must be a piece of duct with a lenght of 1 m. The heater do not operate below the indicated minimum air flow (Vmin).

 

The air heaters may be with steel (NV.e) or with stainless steel tubes (NV.e i).

 

The air heaters, range NV.e/O are factory furnished with separated heating coils in-groups, equally divided in phases.

The air heaters, range NV.e/O connection to the power supply panel should be realized in a way excluding the switching influence of the separate groups upon the other consumers, such as radio and television sets in the close proximity.

The air heaters, range NV.e/R are factory delivered with such protection.

 

The built-in synchronous switcher in air heater's range NV.e/R. is a electronic type, and are the ability of proportionally regulating the power of the air heater, providing constant air temperature (±0,5o C) in the operating premises. There is a pulsing electronic regulators which switch on /off the power of the air heater, providing proportional temperature control in the premises. The switching on/off of the power is performed by passing through the zero point of the sinusoidal curve of the current, excluding television and radio interference in this way.

All this commutations drop-off of the supply panel, at these options and they are changed by the built-in the regulator electronic elements.

The electrical air heater is conform to national safety requirements (written statement No 01.0104/03.048)

 

FUNCTIONAL DATA

 

Type

Installed power

Vnominal

m3/h

Vmin

m3/h

T2

0C

NV.e 5,6-400/200

»5 kW

1100

550

24

NV.e 15-400/200

»15 kW

1100

550

48

NV.e 14-500/350

»15 kW

2500

1250

26

NV.e 28-500/350

»30 kW

2500

1250

41

NV.e 15-600/400

»15 kW

3500

1750

22

NV.e 30-600/400

»30 kW

3500

1750

34

NV.e 45-600/400

»48 kW

3500

1750

46

NV.e 15-700/400

»15 kW

4000

2000

21

NV.e 30-700/400

»30 kW

4000

2000

31

NV.e 45-700/400

»45 kW

4000

2000

42

NV.e 50-700/400

»50 kW

4000

2000

45

 

DIMENSIONS

 

 

Type

P

kW

LO

mm

H

mm

A

mm

A1

mm

A2

mm

B

mm

B1

mm

B2

mm

D

mm

NV.e/O 400/200

Ј 9,4

11,3

13,2

15,1

17

360

390

420

450

480

280

400

419

434

200

219

234

9

NV.e/O 500/350

Ј 17,5

21

24,5

28

31,5

35

360

390

420

450

480

510

430

500

519

534

350

369

384

9

NV.e/O 600/400

Ј 25

30

35

40

45

50

360

390

420

450

480

50

480

600

619

634

400

419

434

9

NV.e/O 700/400

Ј 25

30

35

40

45

50

360

390

420

450

480

510

480

700

719

734

400

419

434

9

 

The specified in the table dimensions are available for the (NV.e/O) range, for the others, the length LO should be rectify as follow:

  1. For   NV.e/R - LR= LO+130 mm
  2. For   NV.e/R.T - LRT= LO+130 mm

  

TYPE KEY

The various type-dimensions of the air heaters are indicated by: Class, Fitting, Dimensions, Installed power and Equipment.

For example:

Ý